product
Location :Home > bone conduction transducer
Name:bone conduction transducer RC-BC70B
Describe:
bone conduction transducer RC-BC70B
Content:
Customer Name |
|
Part No |
RC-BC70B |
|||
Customer’s Model |
|
Description |
Bone conduction transducer 8Ω0.5W |
|||
|
||||||
NO. |
Test Item |
Specifications |
Test condition |
|||
1 |
Impedance |
8 Ω±15% |
AT 800 HZ |
|||
2 |
DCR |
8 Ω±15% |
AT 800 HZ |
|||
3 |
Operation |
Must be normal |
Program source 0.5W |
|||
4 |
Sweep test |
Must be normal |
Sine wave 2 V 170HZ-15KHZ |
|||
5 |
F0 |
170HZ ±20% |
Without baffle |
|||
6 |
Sensitivity |
83±3dB average at 500,2k,4k,10kHZ |
At 0.3 V axis calculated From 0.1MM |
|||
7 |
Rated freq.response |
Fo-----15KHZ |
Sensitivity –10 dB |
|||
8 |
Power input |
Normal 0.5W |
Maximum 1W |
|||
9 |
Distortion |
5% MAX |
At 1KHZ 0.01M 0.5W |
|||
10 |
Life test |
After test,meet Item 3,4&5 |
Pink noies 0.5W 24 hrs 170HZ-15KHZ |
|||
11 |
Heat test |
After test,meet Item 3,4&5 |
72±2℃;20-50%AR.H.48hrs |
|||
12 |
Humidity test |
After test,meet Item 3,4&5 |
40±2℃;90-95%AR.H.48hrs |
|||
13 |
Cold test |
After test,meet Item 3,4&5 |
-25±3℃; -%AR.H.16hrs |
|||
14 |
Slide Shock Test |
Must be normal |
Coasts from 1meter long slide along 75 angles |
|||
15 |
Magnet |
Ne-Fe-B Hard Ferrite oz or g |
||||
16 |
Flux density |
Gauss |
||||
17 |
Net Weight |
2g or 0.123 oz |
||||
18 |
Polarity |
When a positive volts d.c.is supplied from the speaker terminal marked(+)and a Negative volts to the other terminal the diaphram must move toward the front |
||||
19 |
Dimension |
D:16.75mm,H:6.1mm |
||||
20 |
Voice |
|
||||
21 |
Use |