NO. |
Test Item |
Specifications |
Test condition |
||
1 |
Impdeance |
8 Ω±15% |
AT 800 HZ |
||
2 |
DCR |
8 Ω±15% |
AT 800 HZ |
||
3 |
Operation |
Must be normal |
Program source 1.0 W |
||
4 |
Sweeptest |
Must be normal |
Sine wave 2.83 V 200HZ-5KHZ |
||
5 |
F0 |
200 HZ ±20% |
Without baffle |
||
6 |
Sensitivity |
85±3dB average at 500,2k,4k,10kHZ |
At 2.83 V axis calculated From0 .01M |
||
7 |
Rated freq.response |
F0-----20KHZ |
Sensitivity –10 dB |
||
8 |
Power input |
Normal 1.0 W |
Maximum 1.5 W |
||
9 |
Distortion |
5% MAX |
At 1KHZ 1M 1W |
||
10 |
Life test |
After test,meet Item 3,4&5 |
Pink noies 1.0 W 24 hrs 200HZ-20KHZ |
||
11 |
Heat test |
After test,meet Item 3,4&5 |
72±2℃;20-50%AR.H.48hrs |
||
12 |
Humidity test |
After test,meet Item 3,4&5 |
40±2℃;90-95%AR.H.48hrs |
||
13 |
Cold test |
After test,meet Item 3,4&5 |
-25±3℃; -%AR.H.16hrs |
||
14 |
Slide Shock Test |
Must be normal |
Coasts from 1meter long slide along 75 angles |
||
15 |
Magnet |
■Ne-Fe-B □Hard Ferrite oz or g |
|||
16 |
Flux density |
Gauss |
|||
17 |
Net Weight |
4.2 g or 0.148 oz |
|||
18 |
Polarity |
When a positive volts d.c.is supplied from the speaker terminal marked(+)and a Negative volts to the other terminal the diaphram must move toward the front |
|||
19 |
Dimension |
D:16.2mm,H:7.9mm |
|||
20 |
Voice |
|
|||
21 |
Use |