product
Location :Home > bone conduction transducer
Name:RC-BC52 small size bone conduction trasnducer
Describe:
RC-BC52 small size bone conduction trasnducer
Content:
RC-BC52 small size bone conduction trasnducer
|
|||||||||||
Customer Name |
|
Part No |
RC-BC52 |
||||||||
Customer’s Model |
|
Description |
Bone conduction transducer 8 Ω 0.5W |
||||||||
|
|||||||||||
NO. |
Test Item |
Specifications |
Test condition |
||||||||
1 |
Impedance |
8 Ω±15% |
AT 800 HZ |
||||||||
2 |
DCR |
8 Ω±15% |
AT 800 HZ |
||||||||
3 |
Operation |
Must be normal |
Program source 0.5 W |
||||||||
4 |
Sweep test |
Must be normal |
Sine wave 2.0 V 280HZ-5KHZ |
||||||||
5 |
F0 |
280 HZ ±20% |
Without baffle |
||||||||
6 |
Sensitivity |
84.5±3dB average at 500,2k,4k,10kHZ |
At 0.2 V axis calculated From-0.01 MM |
||||||||
7 |
Rated freq.response |
Fo-----15KHZ |
Sensitivity –10 dB |
||||||||
8 |
Power input |
Normal 0.5 W |
Maximum 0.6 W |
||||||||
9 |
Distortion |
5% MAX |
At 1KHZ 1M 0.5W |
||||||||
10 |
Life test |
After test,meet Item 3,4&5 |
Pink noies 0.5 W 24 hrs 240HZ-15KHZ |
||||||||
11 |
Heat test |
After test,meet Item 3,4&5 |
72±2℃;20-50%AR.H.48hrs |
||||||||
12 |
Humidity test |
After test,meet Item 3,4&5 |
40±2℃;90-95%AR.H.48hrs |
||||||||
13 |
Cold test |
After test,meet Item 3,4&5 |
-25±3℃; -%AR.H.16hrs |
||||||||
14 |
Slide Shock Test |
Must be normal |
& |